This field does have measured outcomes on live networks. Schneider Electric digitised 75 substations for Tata Power Western Odisha, serving 2.1 million customers, and reports a 30% cut in power interruption time with 70% targeted. Ameren Missouri deployed more than 500 fault interrupters over five years and reports a 32% improvement in outage duration and 26% in outage frequency, cutting customers per feeder segment from 1,500 to 400.
Money committed · 3 independent sources
2 / 7
ABB completed its acquisition of Netcontrol in May 2026, folding a Nordic specialist in SCADA, remote terminal units and engineering services into its distribution division. In February the same year S&C Electric and Schweitzer Engineering Laboratories paired an interrupter with a digital control over a standard fibre interface, sold explicitly for retrofitting existing installations.
Research
3 / 7
The clearest engineering change is where the fault is located. A 10kV ring isolator from Nanjing Rongtai has each protection device talk only to its immediate neighbours, sharing current direction and fault status, and claims breaker trips within 90 milliseconds before the substation switch acts, against the tens of seconds central coordination takes. A Beijing terminal does the same over the IEC 61850 substation messaging standard, using peer-to-peer GOOSE links.
Market
4 / 7
The thing being sold is a pre-engineered block with a stated switching time and a route onto hardware the utility already owns. ABB's distribution automation solution centres quote fault detection, isolation and restoration in under a second, packaged as pre-configured panels, retrofit programmes and engineering support. S&C and Schweitzer Engineering launched that same shape in February 2026, pairing an interrupter with a digital control over a standard fibre interface and pitching it at retrofit of existing installations.
Strategy
5 / 7
Fault Management holds 1,644 documents and Voltage Management 950. Together that is about 86% of everything in the field. Enabling Technologies holds 219 and Grid Monitoring and Control 164.
Research
6 / 7
A zone is given an operating band and trusted to stay inside it, which is the voltage equivalent of pushing the decision out to the pole. State Grid Fujian runs a regional autonomous mode inside the distribution management system and restores it from active and reactive reserve when it breaks. Guangdong coordinates high and medium voltage from a cloud-edge split.
Market
7 / 7
DTE Energy's automated devices prevented more than 16,000 outages across its territory in 2025, as part of a five-year, $10 billion grid plan that targets 30% fewer outages and half the outage time by the end of 2029. Schneider Electric's work for Tata Power Western Odisha Distribution digitised 75 substations and cut restoration time by 30%, with a stated aim of up to 70%, across 2.1 million customers.
Research
What is being built
Documents by area
1643
951
218
165
Market
What reaches buyers
44
market news items in the last 12 months, up 110% on the 12 before
Nov 2024Oct 2026
Strategy
Where the money goes
Moves in the last four quarters
5
7
12
3
Newest: A predictive-corrective optimization method for circuit breaker configuration in AC/DC hybrid distribution networks · 6 Nov
What's newWhat is newest in this field?
What's new · What is newest in this field?
Interesting new patent families
October 2026 · Ranked by how far each patent goes beyond earlier work.
Patent
What the patent does. Microgrids struggle with poor forecasts, weak risk checks and disconnected controls. The patent links data cleaning, forecasting, risk assessment, resource allocation, simulation and control in a retrained loop. In a 30-day island-microgrid test, curtailment fell to 3.1% from 21.8% with a traditional method.
Patent
What the patent does. Remote grids need faster support, less wasted solar power, and startup without a thermal plant. The patent turns surplus solar electricity into stored heat and uses it to run a closed-loop generator while controlling grid voltage and frequency. In a 1-megawatt test, it cut daily solar curtailment to 99.4%, versus 78.2% for power-distribution control without thermal-shock protection.
Patent
What the patent does. Grid operators struggle to shed enough power without cutting essential services or losing track across network boundaries. The patent models both networks together, prioritizes switches, corrects measurement margins, and adds replacement shedding when switches refuse. In one simulated grid test, it shed 50.5 MW against a 50 MW target after refusals, compared with 38.8 MW initially.
Patent
What the patent does. Grid operators need security checks that do more than flag unusual numbers. The patent links operational tasks, reported measurements and device-control rules, then checks whether their events, timing and dependencies agree before recommending and verifying a block. In described distribution, inverter and substation communication tests, it reports over 99% known-attack detection and over 95% previously unseen-attack detection, versus stated older-method ranges, without a described dataset or protocol.
Patent
What the patent does. Operators struggle to keep active distribution-network models accurate when converters limit current and conditions change. The patent combines disturbance responses, sensitivity patterns and learned probability updates to identify both fixed and changing model settings. No measured numerical result is reported against another method in a stated test.